Common platinum resistance temperature sensor
Product description:
Common platinum resistance temperature sensor
Stainless steel pipe or copper aluminum pipe package, filled with thermal insulation material, waterproof and shockproof performance, suitable for liquid, gas, refrigerated, and a variety of environmental temperature measurement, the sensor is the most widely used.
According to the temperature range of the temperature sensor:
Serial number
Class don't
Operating temperature range
One
General type temperature sensor
Normal atmospheric temperature
20 ~ 85 C
Two
High temperature type temperature sensor
high temperature
50 ~ 150 C
high temperature
50 ~ 200 c
high temperature
50 ~ 300 C
Three
Low temperature type temperature sensor
low temperature
50 ~ 150 C
low temperature
50 ~ 200 c
low temperature
50 ~ 300 C
HX-RS series platinum resistance temperature sensor type selection table
Code
technical parameter
Graduation
P
Pt100
P 10
Pt1000
Accuracy class
A
A
B
B
Applied ambient temperature
One
20 ~ 85 C
Two
50 ~ 150 C
Three
50 ~ 200 c
Four
50 ~ 300 C
Five
Other
Sensor structure
One
Only
Two
Only two
Probe protection tube
Texture of material
S4
SUS304
S6
SUS316
S1
SUS321
S0
Customer specified
Diameter D (mm)
2.5= with 2.5 3= with 3 4= with 4.0 5= with 5.0 6= with 6 7= with 7.0  = 8; 8.0 10= 10 20= 20.0 customer specified
Length L (mm)
15=15, 20=20, 25=25, 30=30, 35=35, 40=40, 45=45, 60=60, 90=90, 100=100, 150=150, 50=50, 200=200,  , 1000=1000 customer specified
Lead
Two
Wire
Two-wire system
Three
Three wire system
Four
Four wire system
One
Material Science
PVC wire RVV
Two
PVC wire RVVP
Three
PVC wire AVVR
Four
Teflon shielded wire
Five
Teflon line
Six
Silicone rubber wire AGR
Seven
Customer specified
Connection terminal
Zero
Tinned wire
One
Cold pressing terminal
Three
Customer specified
Other technical requirements
Customer specified
Order selection of HX-RS series temperature sensors is illustrated by examples:
P10A41S4430350
P10
A
Four
One
S4
Four
Thirty
Three
Five
Zero
Pt1000
A
50 ~ 300 C
Only
SUS304
With 4.0mm
30mm
Three wire system
Teflon line
Tinned wire
HX-RS series of temperature sensors, protective tubes, specifications, dimensions
Unit: mm
Diameter (D)
With 2.5
With 3
With 4
With 5
With 6
Length (I)
Twenty
Fifteen
Thirty
Twenty-five
Thirty
Thirty
Thirty-five
Thirty
Forty
Fifty
Sixty
Forty-five
Fifty
One hundred
Ninety
Sixty
One hundred
One hundred and fifty
One hundred
Two hundred
HX-RS series platinum resistance temperature sensor type selection reference