Integrated intelligent thermocouple temperature transmitter
Product description:
Product number
HX-RS-SBW6480
Product name
Integrated intelligent thermocouple temperature transmitter
Product description
The whole intelligent two wire temperature transmitter
The thermocouple / thermal fuse alarm sensor
The low temperature falling point self calibration
The micro power super load capacity
The input and output isolation
The integrated intelligent thermocouple temperature transmitter is a kind of integrated temperature transmitter. It is composed of temperature measuring probe (thermocouple sensor) and two wire solid electronic unit. In the form of solid modules, the temperature probe is directly installed in the junction box, thus forming an integrated transmitter
Integrated intelligent thermocouple temperature transmitter, the temperature signal within the range of -200~+1600 DEG C conversion signal transmission for two-wire 4~20mA DC to display instrument, regulator, recorder, DCS, to achieve accurate measurement and control of temperature. Integrated thermocouple temperature transmitter has the advantages of simple structure, saving leads, large output, strong anti-interference ability, good linearity, display instrument is simple, solid, has the advantages of anti earthquake proof module grounding protection and current limiting protection, reliable operation.
technical parameter
(1) input signal: thermocouple (K, E, S, R, J, T, N)
(2) output signal: 4 ~ 20mA
(3) linearity: the output signal is linearly corresponding to the temperature
(4) accuracy: less than 0.1%, less than 0.2%
(5) power supply voltage: 9 ~ 30VDC
(6) environmental temperature: -40 ~ +85 centigrade;
(7) the coefficient of temperature drift is + 0.01%/ centigrade
(8) isolation strength: AC1500v 1 minutes between input / output
(9) voltage fluctuation effect: + 0.005% X range / V DC below
(10): galvanic insulation between the input and output more than 100M Omega /DC500V
(11) load capacity: RL= (U-8.0v) /0.022A
(12) voltage input: input impedance above 5M
(13) input detection current: 0.2mA (2w/3w/4w);
(14) thermocouple: input impedance above 5M
(15) fusing alarm detection current: 5 A
Product model
Structural characteristics of integrated intelligent thermocouple temperature transmitter
SBW6480
Without fixing device
SBW6482
Fixed threads with cold ends
SBW6483
Fixed threads without cold ends
SBW6484
Fixed flange
SBW6485
Movable flange
SBW6486
Movable sleeve thread
SBW6487
Fixed thread (tapered protective sleeve)
SBW6488
Movable flange (right angle bend)
SBW6489
The protective sleeves are special materials such as ceramics, corundum, etc., or need special treatment (strong acid and alkali, salt resistance, corrosion resistance, etc.)
For details download, click: http://www.bjhxrs.com.cn/cn/dow.asp, id=70
Examples of structural features are described
Example of structure and shape
Object example
SBW6480 -- without fixing device
SBW6482 - Fixed threads with cold ends
SBW6483 - Fixed threads without cold ends
SBW6484 -- fixed flanges
SBW6485 -- movable flange
SBW6486 -- movable sleeve thread
SBW6487 - Fixed threads (tapered protective sleeves)
SBW6488 -- movable flange (right angle elbow)
Introduction of parameter selection
project
Code
Select item
Thermocouple type
K
K
E
E
S
S
R
R
J
J
T
T
N
N
B
B can be customized according to customer requirements.
Isolation type
Zero
Non isolation
One
Total isolated input / output
Accuracy class
One
0.1%FS
Two
0.2%FS
Three
Customer specified
Flameproof type
Zero
Non flameproof
One
Flameproof type
Assembly form
G
prefabricated
K
Armoured
Junction box
One
Waterproof junction box
Two
Stainless steel terminal box
Three
Integrated explosion-proof junction box
Four
2088 terminal box
Five
The other way: socket type, small box, special custom.
Outer diameter of protective tube
prefabricated
Phi 4 to Phi 20.0mm
Armoured
Phi 3 to Phi 10.0mm
Special specifications
The negotiation order
Total length
TL: no junction box (mm)
Insertion depth
EL: (mm)
Texture of material
4 (SUS304); 6 (SUS316L); 2 (SUS321); 9 (GH3039);
Process connection
When ordering, specify thread size and flange size
range
Within 0~1800 degrees, customer specified
Introduction of some commonly used process connecting threads
Outline structure drawing
Thread specification
Thread L (mm)
The opposite edge S (mm)
H (mm)
S
L
H
S
L
H
M8
Ten
Twelve
Six
M10
Twelve
Fourteen
Six
M12
Fifteen
Sixteen
Eight
M16
Fifteen
Twenty-two
Eight
M20
Eighteen
Twenty-seven
Ten
M27
Thirty
Thirty-two
Fifteen
M33
Thirty-three
Thirty-six
20`
S
L
H
G1/8
Twelve
Fourteen
Six
G1/4
Fifteen
Eighteen
Eight
G3/8
Fifteen
Twenty-two
Eight
G1/2
Eighteen
Twenty-seven
Ten
G3/4
Twenty
Thirty-two
Fifteen
NPT 1/8
Twelve
Fourteen
Six
NPT 1/4
Fifteen
Eighteen
Eight
NPT 3/8
Fifteen
Twenty-two
Eight
NPT 1/2
Eighteen
Twenty-seven
Ten
NPT 3/4
Twenty
Thirty-two
Fifteen
NPT1
Twenty-five
Thirty-eight
Fifteen
Some commonly used fixed flanges are introduced
Fixed flange parameter
Outline of fixed flange
Code
D
D1
D2
D3
D
F1
Ninety-five
Sixty-five
Forty-five
12 or 16
Fourteen
F2
One hundred and five
Seventy-five
Fifty-five
12 or 16
Fourteen
F3
One hundred and fifteen
Eighty-five
Sixty-five
12 or 16
Fourteen
Symbolic description
D: fixed flange diameter D3: protective tube diameter
D1: location hole concentric circle diameter
D: the diameter of the locating hole (4 in number)
Some commonly used movable flanges are introduced
Sketch of movable flange shape
Sketch of movable sleeve flange
Movable flange parameter
Movable sleeve flange parameter
Code
Numerical value (mm)
Explain
Fitting diameter
Code
Numerical value (mm)
Explain
Fitting diameter
D
Seventy
Flange diameter
Ø 12; Ø 16
D
Sixty
Flange diameter
Ø 4; Ø 5
Ø 6; Ø 8
D1
Fifty-four
The concentric diameter of the locating hole is
D1
Forty-two
Location Kong Yuan concentric circle diameter
D
Nine
Diameter of locating hole (3 holes)
D
Nine
Diameter of locating hole (3 holes)
Introduction of common card sleeve thread
Collar thread
Code and size
The outer diameter of armored pipe is d (mm)
Phi 8
Phi 6
Phi 5
Phi 4
M
M16 * 1.5 M12 * 1
M12 * 1
S
22mm
19mm
Sketch of sleeve thread